[poller]
collector_id = "pi-zero-living-room"
device_id = "00000000-0000-0000-0000-000000000000"
interval_seconds = 300
request_timeout_seconds = 20
[smartthings]
base_url = "https://api.smartthings.com/v1"
# For production, set these via SMARTTHINGS_* environment variables.
client_id = ""
client_secret = ""
refresh_token = ""
token_file = "/var/lib/smartthings-windfree/token.json"
# Testing only; current PATs expire after 24 hours:
access_token = ""
access_token_file = ""
[redpanda_connect]
url = "http://127.0.0.1:4195/windfree"
timeout_seconds = 15
[[fields]]
name = "temperature"
component = "main"
capability = "temperatureMeasurement"
attribute = "temperature"
[[fields]]
name = "humidity"
component = "main"
capability = "relativeHumidityMeasurement"
attribute = "humidity"
[[fields]]
name = "mode"
component = "main"
capability = "airConditionerMode"
attribute = "airConditionerMode"
# Samsung models expose WindFree differently. Inspect the complete device status
# and adjust this mapping. Missing mapped fields produce warning/no_data.
[[fields]]
name = "windfree"
component = "main"
capability = "airConditionerFanMode"
attribute = "fanMode"
equals = "windFree"